Deep Sea Electronics DSE327 Automatic Transfer Switch Controller 110 Volt

$122.89

-2%Sale!

The DSE327 is an Automatic Transfer Switch Control Module designed to monitor the voltage of an incoming AC supply from two different sources. This could be from both generator or mains (utility), or a combination of both. The module monitors S1 (Source 1) and in the event of a failure issues a start command to S2 (Source 2). The DSE327 can be ordered in 110 V and 230 V variants.

Once S2 is available and producing an output within limits, the module controls the transfer device and switches the load from S1 to S2. Once the S1 supply returns to within limits, the module commands a load return to S1 and shuts down S2. Various timing sequences are available to prevent nuisance starting on minor supply breaks.

OVERALL SIZE
72 mm x 90.5 mm x 65 mm (2.8” x 3.6” x 2.6”)

WEIGHT
0.3 kg

PRODUCT VARIANTS
0327-01 – 327 Auto Transfer Switch Control Module (230 Volt)
0327-02 – 327 Auto Transfer Switch Control Module (110 Volt)
0327-03 – 327 Auto Transfer Switch Control Module (230 Volt – 10 Second Delay)

MAXIMUM OPERATING/STANDBY CURRENT

230 V (0327-01):
Typical  @ 230 V, 50 Hz
S1
I RMS = 75 mA, Power  = 0.9 W
S2
I RMS = 50 mA, Power  = 0.6 W

110 V (0327-02):
Typical  @ 110 V, 50 Hz
S1
I RMS = 70 mA, Power  = 0.8 W
S2
I RMS = 50 mA, Power  = 0.5 W

VOLT FREE OUTPUTS

START/RUN N/C
5 A, 250 V AC
LOADING OUTPUT x2
5 A, 250 V AC

S1 & S2

110 V (0327-02):
VOLTAGE RANGE
110 V – 50Hz to 70 Hz
85V to 150 V AC (L-N)

230 V (0327-01)
VOLTAGE RANGE
230 V – 40Hz to 60 Hz
180 V to 300 V AC (L-N)
SKU: 0327-02 Category:

Description

The DSE327 is an Automatic Transfer Switch Control Module designed to monitor the voltage of an incoming AC supply from two different sources. This could be from both generator or mains (utility), or a combination of both. The module monitors S1 (Source 1) and in the event of a failure issues a start command to S2 (Source 2). The DSE327 can be ordered in 110 V and 230 V variants.

Once S2 is available and producing an output within limits, the module controls the transfer device and switches the load from S1 to S2. Once the S1 supply returns to within limits, the module commands a load return to S1 and shuts down S2. Various timing sequences are available to prevent nuisance starting on minor supply breaks.

OVERALL SIZE
72 mm x 90.5 mm x 65 mm (2.8” x 3.6” x 2.6”)

WEIGHT
0.3 kg

PRODUCT VARIANTS
0327-01 – 327 Auto Transfer Switch Control Module (230 Volt)
0327-02 – 327 Auto Transfer Switch Control Module (110 Volt)
0327-03 – 327 Auto Transfer Switch Control Module (230 Volt – 10 Second Delay)

MAXIMUM OPERATING/STANDBY CURRENT

230 V (0327-01):
Typical  @ 230 V, 50 Hz
S1
I RMS = 75 mA, Power  = 0.9 W
S2
I RMS = 50 mA, Power  = 0.6 W

110 V (0327-02):
Typical  @ 110 V, 50 Hz
S1
I RMS = 70 mA, Power  = 0.8 W
S2
I RMS = 50 mA, Power  = 0.5 W

VOLT FREE OUTPUTS

START/RUN N/C
5 A, 250 V AC
LOADING OUTPUT x2
5 A, 250 V AC

S1 & S2

110 V (0327-02):
VOLTAGE RANGE
110 V – 50Hz to 70 Hz
85V to 150 V AC (L-N)

230 V (0327-01)
VOLTAGE RANGE
230 V – 40Hz to 60 Hz
180 V to 300 V AC (L-N)

Additional information

Weight 3 lbs