Deep Sea Electronics DSE701 MKII Manual & Auto Start Control Module

Original price was: $235.07.Current price is: $230.37.

-2%Sale!

**Please Note: The DSE701-05 has been discontinued and is no longer available. If ordered, the recommended replacement DSE3110-01 will be shipped.

The DSE701 MKII is a compact control module that offers a range of features for single-set applications. The controller can be used in manual or auto start mode.

OVERALL SIZE
72 mm x 72 mm x 38 mm (2.8” x 2.8” x 1.5”)
Excludes Key Switch

PANEL CUTOUT SIZE
68 mm x 68 mm (2.7 ” x 2.7″)

MAXIMUM PANEL THICKNESS
8.0 mm (0.3”)

WEIGHT
0.14kg

PRODUCT VARIANTS
0701-05 – 701MKII Manual & Auto Start Control Module

DC SUPPLY

CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without internal batteries.

MAXIMUN OPERATING CURRENT
26 mA at 12 V, 27 mA at 24 V

MAXIMUM STANDBY CURRENT
20 mA at 12 V, 21 mA at 24 V

CHARGE/FAIL EXITATION RANGE
0 V TO 35 V

OUTPUTS

START
Solid state 1.2 A negative grounding terminal

RUN
Solid state 1.2 A negative grounding terminal

PRE-HEAT
Solid state 1.2 A negative grounding terminal

GENERATOR

VOLTAGE RANGE
15 V – 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

 

SKU: 0701-05 Category:

Description

**Please Note: The DSE701-05 has been discontinued and is no longer available. If ordered, the recommended replacement DSE3110-01 will be shipped.

The DSE701 MKII is a compact control module that offers a range of features for single-set applications. The controller can be used in manual or auto start mode.

OVERALL SIZE
72 mm x 72 mm x 38 mm (2.8” x 2.8” x 1.5”)
Excludes Key Switch

PANEL CUTOUT SIZE
68 mm x 68 mm (2.7 ” x 2.7″)

MAXIMUM PANEL THICKNESS
8.0 mm (0.3”)

WEIGHT
0.14kg

PRODUCT VARIANTS
0701-05 – 701MKII Manual & Auto Start Control Module

DC SUPPLY

CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without internal batteries.

MAXIMUN OPERATING CURRENT
26 mA at 12 V, 27 mA at 24 V

MAXIMUM STANDBY CURRENT
20 mA at 12 V, 21 mA at 24 V

CHARGE/FAIL EXITATION RANGE
0 V TO 35 V

OUTPUTS

START
Solid state 1.2 A negative grounding terminal

RUN
Solid state 1.2 A negative grounding terminal

PRE-HEAT
Solid state 1.2 A negative grounding terminal

GENERATOR

VOLTAGE RANGE
15 V – 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

 

Additional information

Weight 2 lbs